Safety and first aid

Fire damaged on-site wastewater systems

  • If your system is damaged and presents an immediate safety risk, action should be taken as soon as practicable to make it safe.
  • It is recommended that damaged on-site wastewater systems are not used until repaired or replaced.

On-site wastewater systems can be easily damaged during a fire. This includes septic tanks (primary treatment systems), secondary treatment systems (STS), aerated wastewater treatment systems (AWTS), and their land application systems, for example plastic leach drains, sprinklers and below ground drippers and connection pipes.

Plastic and fibreglass on-site wastewater systems, or systems made with plastic components, are more susceptible to damage than concrete tanks particularly if installed above ground. This includes shallow PVC pipes, plastic tanks and sumps, and plastic irrigation pipework which may be installed above or below ground. Pumps and other equipment with electrical components may also be damaged.

If your system is damaged and presents an immediate safety risk, action should be taken as soon as practicable to make it safe. For example, if the lid is missing, place a temporary cover or fencing around the system to prevent access to the area. It is recommended that damaged on-site wastewater systems are not used until repaired or replaced.

Avoid driving or walking near a fire-affected system until it is assessed by a licensed plumber or service technician familiar with on-site wastewater systems.

Contact with effluent or untreated wastewater from damaged on-site wastewater systems can cause illness and should be avoided at all times.

Actions

Due to the risks associated with using systems after fire, the following actions are recommended:

  • If the on-site systems are damaged, make arrangements to repair the system as soon as possible to prevent sewage from backing up into the house.
  • Avoid driving or walking near underground pipes, tanks and tank covers and their land application systems, which may have been weakened or damaged.
  • Reduce water use as much as possible until the system is inspected and repaired by:
    • reducing the frequency of toilet flushing for liquid waste
    • taking shorter showers or shower elsewhere
    • limiting laundry and dishwashing as much as possible. If possible avoid using automatic clothes washers and dishwashers.
  • If the power has not been restored, the septic tank can be used as a temporary holding tank and pumped out periodically, provided the tank is not damaged. You may need to disconnect the pump (if present) and block the outlet to the land application area. If the tank is significantly damaged and can’t be used as a temporary holding tank, do not use the system until it is repaired or replaced.
  • Once power is restored, ponding may occur near the wastewater system and these areas should be avoided. Contact a licenced plumber or authorised service technician to reassess the system.
  • Replace shallow PVC pipes if they have melted as they may cause blockages.
  • Repair or replace damaged electrical components and pumps as soon as possible.

For further advice, please contact Environmental Health Directorate on 9222 2000 or email ehinfo@health.wa.gov.au

Where to get help

Last reviewed: 13-10-2023

This publication is provided for education and information purposes only. It is not a substitute for professional advice. Information about a service, product or treatment does not imply endorsement and is not intended to replace professional advice. Readers should note that over time currency and completeness of the information may change. All users should seek advice from a qualified professional for answers to their questions.

Questions? Ask your local government environmental health services